{"product_id":"whi-control-sk20pphs2-auto-restart-2-2bar-whi-sk20pphs2","title":"WHI CONTROL SK20PPHS2 AUTO RESTART 2.2BAR WHI-SK20PPHS2","description":"\u003cdiv class=\"widget-product-field info-group widget-product-field-ProductDescription\"\u003e\n\u003cdiv class=\"info-group-content\"\u003eAUTO RESTART AUTOMATIC PUMP CONTROLLER PLUG AND PLAY with IEC lead and pressure gauge. 240V, 1ph, 10A max, 1.5kW, 2.0hp, IP65, Ports 1” BSPM. Cut in pressure 2.2 bar. Min pump pressure 400kPa. 12 Month Warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"widget-product-field info-group widget-product-field-ProductFeatures\"\u003e\n\u003ch5 class=\"info-heading\"\u003eFeatures\u003c\/h5\u003e\n\u003cdiv class=\"info-group-content\"\u003e\n\u003cdiv class=\"col-1-2\"\u003e\n\u003cp\u003eThe White International WHI-SK20PPHS2 controllers are devices used to control electric 240V pumps of 1.5kW or less.\u003c\/p\u003e\n\u003cp\u003eThe controller monitors both the pressure and the flow. It controls the operation of the pump automatically. Because of its design, there is no need for a separate pressure (expansion) tank, nor is there any need to adjust start and stop pressures as per traditional pressure switches.\u003c\/p\u003e\n\u003cp\u003eThe unit will protect the pump should the water supply fail (due to blockage in the pipe or tank running dry) and will automatically restart normal operation once water is restored.\u003c\/p\u003e\n\u003ch5\u003eFeatures and Benefits\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eStarts and stops the pump automatically when the tap is open or closed. This means the pump does not need to be turned off manually.\u003c\/li\u003e\n\u003cli\u003eMaintains a constant pressure from the pump during operation resulting in a reliable water supply.\u003c\/li\u003e\n\u003cli\u003eAutomatically stops the pump in the situation of no flow (due to inlet pump blockage) and will automatically resume normal operation once the blockage is removed.\u003c\/li\u003e\n\u003cli\u003eAutomatically restarts the pump in the event of power failure. This gives the homeowner peace of mind that the unit will continue to operate even if they are away for a long period of time.\u003c\/li\u003e\n\u003cli\u003eThe controller eliminates pressure fluctuations at flows as low as 1L\/min.\u003c\/li\u003e\n\u003cli\u003ePlug and play leads (IEC type) are installed on the controller so that a licensed electrician is not required to replace the controller.\u003c\/li\u003e\n\u003cli\u003eThe controller incorporates an inbuilt pressure gauge to enable the homeowner to monitor the system pressure without the need of a separate inline pressure gauge. The pressure gauge can also diagnose nuisance upstream water.\u003c\/li\u003e\n\u003cli\u003eDrinking water AS\/NZS4020 approved in Australia and New Zealand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-1-2 no-print\"\u003e\n\u003ca href=\"https:\/\/www.whiteint.co.nz\/documents\/Pumps\/White%20International%20Automatic%20Restart%20Pump%20Controllers%20Brochure.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"White International Automatic Restart Pump Controllers Brochure\" width=\"228\" src=\"https:\/\/www.whiteint.co.nz\/documents\/Pumps\/White%20International%20Automatic%20Restart%20Pump%20Controllers%20Brochure.jpg\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.whiteint.co.nz\/documents\/Pumps\/White%20International%20Automatic%20Restart%20Pump%20Controllers%20Brochure.pdf\" class=\"btn primary\" rel=\"noopener\" target=\"_blank\"\u003eView Brochure\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"grid-row\"\u003e\n\u003cbr\u003e\n\u003ch5\u003eConstruction Characteristics\u003c\/h5\u003e\n\u003ctable class=\"cv-table-1\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cv-table-row-0\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eInlet\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1\" BSP male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-1\"\u003e\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-2\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eOutlet\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1\" BSP male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-3\"\u003e\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-4\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eBuilt in non-return valve\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-5\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eNo flow\/loss of prime protection\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-6\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eManual start switch (RESET)\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-7\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eVoltage LED (GREEN power on light)\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-8\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003ePump working LED (ORANGE pump on light)\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-9\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eNo flow LED (RED failure light)\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-10\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003e1.5 metre lead and 3 pin Australian\/New Zealand plug\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-11\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003e0.6 metre pump power lead, plug and play\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-12\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eInbuilt 10 bar pressure gauge\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch5\u003eTechnical Information\u003c\/h5\u003e\n\u003ctable class=\"cv-table-2\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cv-table-row-0\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e220V (-6%) \/ 240V (+6%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-1\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e16(8) Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-2\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eMaximum kW\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1.5kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-3\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-4\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-5\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eMaximum Water Temperature\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e60 deg C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-6\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eStarting Pressure\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e2.2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-7\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eRecommended Minimum Pump Pressure Required  \u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e4.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-8\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-9\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eMinimum Flow\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1.0 l\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5 class=\"info-heading\"\u003eProduct Code\u003c\/h5\u003e\n\u003cdiv class=\"info-group-content\"\u003eWHI-SK20PPHS2\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003ch5 class=\"\"\u003eTechnical Specifications\u003c\/h5\u003e\n\u003ctable class=\"content-table headings-left cv-table-0\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"even cv-table-row-0\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003eWhite International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd cv-table-row-1\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003ePump Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even cv-table-row-2\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003eBar\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd cv-table-row-3\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003eKilo Watts\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even cv-table-row-4\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003eCasing Material\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003eTechnopolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd cv-table-row-5\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003ePort Size Inlet\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1\" BSPM Inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even cv-table-row-6\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003ePort Size Outlet\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1\" BSPM outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd cv-table-row-7\"\u003e\n\u003ctd class=\"type cv-table-cell-0\"\u003eVolts\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.whiteint.co.nz\/documents\/DataSheets\/711942_100.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eProduct Information and Data Sheets\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.whiteint.co.nz\/documents\/Brochures\/711942_200.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eProduct Brochures1\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.whiteint.co.nz\/documents\/Brochures\/711942_201.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Brochures2\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.whiteint.co.nz\/documents\/Manuals\/711942_500.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation and Installation Manuals\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.whiteint.co.nz\/documents\/Certificates\/711942_700.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCertificates \u0026amp; Compliance Information\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003ePrice includes GST\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Malmaks Water Shop Ltd.","offers":[{"title":"Default Title","offer_id":43451358445647,"sku":null,"price":241.5,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0286\/2969\/6591\/files\/711942.jpg?v=1753526537","url":"https:\/\/shop.malmakswatershop.co.nz\/products\/whi-control-sk20pphs2-auto-restart-2-2bar-whi-sk20pphs2","provider":"Malmaks Water Shop Ltd.","version":"1.0","type":"link"}